Archive for the ‘R-value’ Category

Efficient Homes | Spray Foam Insulation27 May

Living Room 300x224 Efficient Homes | Spray Foam Insulation

Warm Home Insulation

Insulation is very important when it comes to houses and buildings.  Fiberglass was the most common type of insulation until the introduction of the Polyurethane foam insulation system.  Polyurethane is known to be a closed-cell material ensuring that the indoors is kept free from air and moisture.

The process of installing this type of insulation is also very simple and does not require anything else to hold it in place.  The foam is sprayed into the walls or between the ceiling and the roof.  The foam then starts to expand to about 100 times its original volume, thus, making its way to all parts of the wall and leaving no room for air or moisture to seep in.  It can be installed even in the hardest places to reach without settling or shrinking.

This type of residential insulation is highly recommended by the US Department of Energy because of its energy efficiency.  Spray foam insulation has an R-value of 6 to 8 per inch, much higher than that of fiberglass which only has an R-value of 2 to 4.  This means that any heating or cooling equipment would not require as much fuel as it would need with any other types of insulation systems.  Polyurethane, once installed in between walls and ceilings, does not emit any harmful odors or fumes.  Its efficiency in sealing out moisture makes it impossible for mold and mildew to grow, thus, reducing the risks of allergies.  It is very effective in keeping bugs and rodents out as the spray foam material has no food value for them whatsoever.

The great thing about spray foam insulation is that it actually adds to the structural strength of a house or building without adding too much weight to it.  So regardless of what material a house is made of, polyurethane spray foam insulation will adhere easily and work efficiently.

For more information about Spray Foam and how it can work for you, contact EcoLogic Spray Foam Insulation at 1 888 880-8420.

Tags : , , ,
Posted in : Common Questions, Environment, R-value | Comments Off

The concept of Insulation in Canada13 May

buildingScienceHouse The concept of Insulation in Canada

Insulation foremost to efficient building

Today, common Insulation creates moisture problems

We must adopt modern, efficient insulation materials.  Insulation material in Canada needs to be updated to effectively protect our homes and reduce our energy dependency.  Canada’s often-humid climate is characterized by high humidity throughout the year in places. The effect of this climate on buildings and residential housing in particular is significant.  Moisture drive is the main issue though the seasonal temperature range exceeds 40 degrees Celsius (80 degrees in places) and contributes to structural damage and energy consumption over the course of the year.

Canadian homes are almost all insulated with fiberglass insulation though recently other fibrous materials such as cellulose and mineral wool have made inroads to the market.  Insulation in Canada must provide protection from moisture drive as well as thermal protection because of our climate.  In Canada, insulation needs to perform as an air barrier and a vapor barrier.  While traditional walls are built with air barrier and vapor barrier layers to protect the fibrous insulation, these have resulted in costly damage on an enormous scale in Canada’s climate.  Either because of poor installation, failure to seal with caulking (in older homes), post installation penetrations placed in the wall by homeowners or failure of the sealants over time, this technique fails to stand up to the environment.

Modern insulation is more costly to install, but save far more money in time.

Insulation in Canada is cheap and readily available and most homeowners give it little thought because it is so widely accepted that insulation comes in plastic bags and is pink in color.  This ready acceptance needs to be challenged for in Canada, pink insulation is responsible for water damage from water ingress, vapor drive from the interior side of the wall and the resultant mold and mildew issues that this soon to be trapped water creates.

Spray Foam Insulation results in energy efficiency, and healthy indoor air quality.

Homeowners need spray foam insulation in Canada and need to familiarize themselves with its cost, benefits and limitations for no other product can withstand the high humidity of our climate.  Spray foam insulation in Canada provides an air barrier/vapor barrier and thermal insulation in a single application.  Spray Foam insulation is made of billions of tiny plastic wrapped bubbles which are not subject to air movement or moisture drive, making it the very best insulation material for Canada cold climate on the market.  While more expensive to install, spray foam insulation results in lower utility bills, less structural damage over the life of the building, longer building life and a far lower overall ownership costs than fibrous products.  Be sure to ask how EcoLogicfoam insulation can meet your needs.

Tags : , , , , , , , ,
Posted in : Common Questions, Environment, R-value, building envelope | 6 Comments »

The R-value is a modern fairy tale.6 May

Vaulted Great room 199x300 The R value is a modern fairy tale.

R-Value alone fails to represent performance

That oldest of fairy tales: R-Value

It’s a fairy tale that has been so touted to the American consumer that it now has a chiseled in-stone status. But the saddest part of this fairy tale is that the R-value by itself is almost a worthless number.

It is impossible to define an insulation with a single number. To do so, we must know more. So why do we allow the R-value fairy tale to perpetuate? I don’t know. I don’t know if anybody knows. What we do know is that the R-value fairy tale obviously favors fiber insulation.

Consider the R-value of an insulation after it has been submersed in water or as a 20 mile-per-hour wind blows through it. In either of these scenarios, the R-value of fiber insulations goes to zero. But those same conditions barely affect solid insulations. That’s why I believe that R-value numbers are misleading, meaningless numbers, unless we know other characteristics.

In all probability, no one would ever buy a piece of property knowing only one of its dimensions. Suppose someone offered a property for $10,000 dollars and told you it was a seven. You would instantly wonder what that number referred to: Seven acres? Seven square feet? Seven miles square? What? You would also want to know the property’s location: In a swamp? On a mountain? In downtown Dallas? In other words, one number cannot accurately describe anything, and that includes the value of an insulation.

Code Requirements Promote R-Value

Nevertheless we have Code bodies mandating R-values of 20s or 30s or 40s. But a fiber insulation with an R-value of 25 placed in an improperly sealed house will allow wind to blow through it as if there were no insulation. Maybe the R-value is accurate when the material is lab tested. But a lab environment may not even remotely duplicate conditions in the real world.

Consequently, we must start asking for some additional dimensions to our insulation. We need to know its resistance to air penetration, to free water, and to vapor drive. We must begin demanding the R-value of an insulating material after it is subjected to real world conditions.

As it is currently used, an R-value is a number that is supposed to indicate a material’s ability to resist heat loss. It is derived by taking the k-value of a product and dividing it into the number one. The k-value is the actual measurement of heat transferred through a specific material.

Test to Determine the R-Value

The test used to produce the k-value is an ASTM (American Society for Testing and Materials) test. This ASTM test was designed by a committee to give us measurement values that – they hoped – would be meaningful. Unfortunately, the test was designed with a flaw or bias. Because of the way it’s designed, the test favors fiber insulations: fiberglass, rock wool and cellulose fiber. Very little input went into the test for solid insulations, such as foam glass, cork, expanded polystyrene or urethane foam.

Nor does the test account for air movement (wind) or any amount of moisture (water vapor). In other words, the test used to create the R-value is a test in non-real-world conditions. For instance, fiberglass is generally assigned an R-value of approximately 3.5. It will only achieve that R-value if tested in an absolute zero wind and zero moisture environment. Zero wind and zero moisture are not real-world. Our houses leak air, all our buildings leak air, and they often leak water. Water vapor from the atmosphere, showers, cooking, breathing, etc. constantly moves back and forth through walls and ceilings. If an attic is not properly ventilated, water vapor from inside a house will very quickly semi-saturate the insulation above the ceilings. Even small amounts of moisture will cause a dramatic drop in a fiber insulation’s R-value — as much as 50 percent or more.

Vapor Barriers, not just R-Values

We are told, with very good reason, that insulation should have a vapor barrier on the warm side. Which is the warm side of the wall of a house? Obviously, it changes from summer to winter — even from day to night. In a wintry 20 F below zero environment, the inside of an occupied house will certainly be the warm side. But during sunshiny summer months, the outside will be the warm side.

Sometimes a novice owner or builder will put vapor barriers on both sides of the insulation. Vapor barriers so placed generally prove to be disastrous. It seems the vapor barriers stop most of the moisture but not all. Consequently, small amounts of moisture move into the fiber insulation, between the two vapor barriers and become trapped. The moisture accumulates as the temperature swings back and forth. This accumulation can become a huge problem. It can eventually total buckets of water that saturate the fiberglass. We have re-insulated a number of potato storages that originally were insulated with fiberglass and a vapor barrier on both sides. Fiber insulation needs ventilation on one side; therefore, the vapor barrier should go on the side where it will do the most good.

Convection Losses in Loose-Fill Insulation

See Figure 4.1
Most people know that air penetrates the walls of a house. In fact, when the wind blows across some homes, its tenants can feel it. But what most people, including many engineers, do not realize is that there are very serious convection currents that occur within fiber insulations. These convection currents rotate vast amounts of air, but they are not fast enough to feel or even measure, with any but the most sensitive instruments. Nevertheless, the air constantly carries heat from the underside of the fiber pile to the top side, letting it escape. If we seal off the air movement, we generally seal in water vapor. That additional water often condenses and can become a moisture-source that rots the structure. The water, as a vapor or condensation, seriously decreases an insulation value — the R-value. he only way to deal with a fiber insulation is to ventilate. But ventilating means moving air that also decreases the R-value.

pastedGraphic 6 The R value is a modern fairy tale.

Figure 4.1

At very cold temperatures, when the temperature difference across the attic insulation reaches a certain critical point, convection within the insulation can reduce R-value. (J.D. Ned Nisson, “Attic Insulation Problems in Cold Climates,” Energy Design Update, March 1992, 42-43)

The filter medium for most furnace filters is fiberglass — the same spun fiberglass used as insulation. see Figure 4.2 Fiberglass is used for an air filter because it has less impedance to the air flow, and it is cheap. In other words, air flows through a furnace filter very readily. All well and good for a furnace filter – but can that same material effectively insulate a structure? Can you imagine insulating a house by stuffing furnace filters into the walls and ceiling? Tremendous air currents blow through the walls of a typical home. To demonstrate, hold a lit candle near an electrical outlet on an outside wall when the wind is blowing. That flame will flicker and may even go out. The average home with all its doors and windows closed has a combination of air leaks equal to the size of an open door. Even if we do a perfect job of installing fiber insulation in our house and bring the air infiltration close to zero from one side of the wall to the other, we still do not stop air from moving vertically through the insulation itself, in ceilings and walls.pastedGraphic 7 The R value is a modern fairy tale.

Figure 4.2

Can you imagine insulating a house by stuffing furnace filters into the walls and ceiling? Tremendous air currents blow through the walls of a typical home.

Solid Insulations

The best known solid insulation is expanded polystyrene. Other solid insulations include cork, foam glass and polyisocyanate or polyisocyanurate board stock. The last two are variations of urethane foam. Each of these insulations is ideally suited for many uses. Foam glass has been used for years on hot and cold tanks, especially in places where vapor drive is a problem. Cork is of course a very old standby, often used in freezer applications. EPS or expanded polystyrene is seemingly used everywhere – from throwaway drinking cups and food containers to perimeter foundation insulation, masonry insulations, etc. Urethane board stock is becoming the standard for roof insulation, especially for hot mopped roofs. It is also widely used for exterior sheathing on many new houses. The R-value of the urethane board stock is of course better than any of the other solid insulations. All of these solid insulations perform far better than fiber insulations whenever there is wind or moisture involved.

Most solid insulations are installed as sheets or board stock, and most suffer from one very common problem. They generally don’t fit tight enough to prevent air infiltration. And if the wind gets behind them, it matters not how thick these board stocks are. We see this often in masonry construction where board stock is used between a brick and a block wall. Unless the board stock is actually physically glued to the block wall, air will infiltrate behind it. When this happens, the board stock becomes virtually worthless, since the air flows through the weep holes in the brick and around the insulation negating its effectiveness. Great care must be exercised in placing solid insulations. The brick ties need to be fitted at the joints and then sealed to prevent air flow behind the insulation.

Spray-in-place polyurethane is the only commonly used solid insulation that absolutely protects itself from air infiltration. When it is properly placed between two studs or against a concrete block wall or wherever, the bonding of the spray plus the expansion of the material in place creates a total seal. It’s almost impossible to overestimate this total seal. In my opinion, most of the heat loss in the walls of a home has to do with the seal, rather than the insulation.

Heat does not conduct horizontally nearly as well as it does vertically. Therefore, if a home had no insulation in its walls, but did have an absolute airtight seal, there would not necessarily be a huge difference in heat loss. But this would not be the case if ceiling insulation was missing.

Spray-in-place polyurethane can most effectively stop air infiltration. It is the only material that properly applied fills in the corners, cripples, double studs, bottom plates, top plates, etc. The R-value of a material is of no interest or consequence if air can get past it.

Case Studies

During the 1970s in Idaho’s Snake River Valley, my firm insulated the walls of many new homes with 1.25 inches of spray-in-place polyurethane foam. In 1970, the popular number for the R-value of one inch of urethane foam was 9.09 per inch. Using this value, we were putting an R of 1.25 × 9.09 = 11.36 in the walls. This was much less than the R = 16 claimed by fiberglass insulators. Today, using ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) published charts, we would only be able to claim an R-value for the 1.25 inches of 7.5 to 9. Neither of these numbers make for a very high R-value. But in reality, our insulation customers invariably thanked us for the savings in their heat bills. Many told us that their heating bills were half of what their neighbors paid. They felt that they saved the cost of the polyurethane in one or, at most, two years. Most of these customers were savvy people. They would not have paid the extra to get the urethane insulation if it had not been better. Nevertheless, what I call “Case Studies,” some people might call “anecdotal evidence.” That’s okay. Anecdotal evidence is also compelling and very real in our world.

R-Value vs. Temperature

About mid 1975, I received a call from a division manager of a major fiberglass insulation manufacturer. The caller said, “I understand that you are spraying polyurethane in the walls of homes.” I told him that was true. He was calling because we were cutting into fiberglass insulation sales in our area. He asked, “How can you do it?”

I knew what he meant. He wanted to know how I could look folks in the eye and sell them a more expensive insulation instead of cheap fiberglass. I told him the way I did it was with a spray gun. Of course, that wasn’t the answer he wanted. He wanted to know why I did not feel guilty. I told him about insulating one of two nearly identical houses built side-by-side. We insulated the walls of one with 1.25 inches of urethane. Its near-twin was insulated with full, thick fiberglass batts by a reputable installer. Not only did we use just 1.25 inches of urethane as the total wall insulation, but we had the builder leave off the insulated sheathing. At the end of the first winter, the urethane insulated home had a heating bill half of its neighbor. Again, such evidence is not terribly scientific, but it is very real. I am not sure that the manager was convinced, but it should be noted: in the following year, that same company jumped into the urethane foam supply business.

One and a quarter inch of polyurethane sprayed properly in the wall of a house will prevent more heat loss than all the fiber insulation that can be crammed in the walls — even up to an eight-inch thickness. Not only does the polyurethane provide better insulation, it provides the house with significant additional strength.

Brent was an early client of mine for whom I had insulated several potato storages. He knew what spray-in-place urethane insulation could do. When he decided to build his new, very large, very fancy new home, he asked me to insulate it. The builder pitched a fit. He didn’t need any of that spray-in-place urethane in his buildings. He made his buildings tight, and fiberglass was just as good.

Brent told the builder, “I know who is going to insulate the building. It is not as definite as to who is going to be the contractor. You can make up your mind. We are going to have the urethane insulation and you build the building, or we are going to have the urethane insulation, and I will have someone else build the building.” It didn’t take the contractor long to decide he wanted to use urethane insulation.

R-value tables are truly part of the fairy tale. They chart solid and fiber insulations side-by-side, implying that they can be compared. See Figure 4.3 The fact is, without taking installation conditions into account, comparisons are meaningless. Spray-in-place urethane foam provides its own vapor barrier, water barrier and wind barrier. None of the other insulations are as effective without special care taken at installation. Fiber insulations must be protected from wind, water and water vapor. Again, the tables need a second table to state installation conditions.

pastedGraphic 8 The R value is a modern fairy tale.

Figure 4.3

“There is a problem with loose-fill fiberglass attic insulation in cold climates. It appears that, as attic temperature drops below a certain point, air begins to circulate into and within the insulation, forming ‘convective loops’ that increase heat loss and decrease the effective R-value. At very cold temperatures (-20 F), the R-value may decrease by up to 50%. “In full-scale attic tests at Oak Ridge national Laboratory, the R-value of 6 inches of cubed loose-fill attic insulation progressively fell as the attic air temperature dropped. At -18 F, the R-value measured only R-9. The problem seems to occur with any low-density, loose-fill fibrous insulation. (J.D. Ned Nisson, “Attic Insulation Problems in Cold Climates,” Energy Design Update, March 1992, 42-43)

Consider these case studies:

See Figure 4.4
Meadow Gold, a dairy product company, was going to build a freezer in Idaho Falls, Idaho. Chet, Meadow Gold’s plant manager, was a good friend of the local Butler Building dealer, who was a good friend of mine. A Butler Building insulated with expanded polyurethane does not make an efficient freezer. The three of us knew that, so we got together and planned a freezer that would accommodate Meadow Gold’s needs, yet be built of a Butler Building and be properly insulated. This transpired during my first year of spraying polyurethane foam; I believed all the literature and knew that what we were doing was going to be just right.

pastedGraphic 9 The R value is a modern fairy tale.

Figure 4.4

With the lowest K-factor and highest R-value, urethane foam can provide more thermal resistance with less material than any other insulation.

It turned out even better. The then current R-value table showed one inch of urethane equal to 2.5 inches of expanded polystyrene. So, I suggested we spray the metal building with four inches of urethane to replace the 10 inches of expanded polystyrene normally used by Meadow Gold for freezers.

I sprayed the walls and under the slab with four inches, and I sprayed the underside of the roof with five inches of urethane – fifth inch added as a safety margin.

During this process, Chet began worrying. After all, he had stuck his neck out by going with a nontraditional insulation in a nontraditional structure. Well, the building progressed on schedule, but the equipment to cool it did not arrive on time. By summer, only one of two refrigeration compressors had arrived. But based on using 10 inches of expanded polystyrene and per Meadow Gold’s engineers, two compressors were needed for efficient freezing.

Faced with this predicament, Chet considered an alternative: one of the older freezers that had been used as a cooler could be turned back into a freezer. Then, with just one compressor, the new building could be made into a cooler. It was not a satisfactory arrangement, but it maybe could work.

Chet also insisted that as soon as he turned on the freezer equipment he would know if the building would work. When I pressed him, he said that normally it takes five days to bring a freezer down to -10 F — the temperature needed for ice cream. So, Chet turned on the new freezer with its one compressor. By the second morning, the temperature dropped to -18 F! Chet and Meadow Gold had their freezer. It ran the entire summer using only the single compressor.

A few weeks after the freezer’s start-up, a Meadow Gold engineer from Chicago visited me. He wanted to know exactly what we had done to insulate the freezer. One compressor should not have been able to hold the temperature as it did. I explained exactly what we had done. He seemed satisfied and left.

But several more weeks went by and he showed up again – this time with his boss. We went to the plant; using an ice pick, we verified the foam’s thickness. It was, indeed, four inches in the walls and five inches in the ceiling. But again, both engineers reiterated that the building should not be operating as it was. What they were telling me was that even though I had used one inch of urethane to replace 2.5 inches of expanded polystyrene, the building was still requiring only 50 percent of normal compressor power for cooling. As you can imagine, the experience made me a lot bolder, and I used the information to sell more freezer insulation jobs.

A 60,000 square foot freezer in Clearfield, Utah became one of our largest freezer insulation projects. I persuaded Bob, my friend and the general contractor building this new, all-concrete freezer, into letting us insulate it with spray-in-place polyurethane foam. This building was the twelfth in a chain of freezers. Bob took it upon himself to switch from the usual ten inches of expanded polystyrene to four inches of urethane with a fifth inch on the roof. The building was built with tilt-up concrete insulated on the interior side of the concrete with spray-in-place urethane. We then sprayed on a three-fourths of an inch thick layer of plaster as a thermal (fire) barrier. Over the prestressed concrete roof panels, we put five inches of spray-in-place urethane and then, following the urethane manufacturer’s specifications, covered it with hot tar and rock.

On my last day on this job, the owner showed up. He had expected to see ten inches of expanded polystyrene – not four inches of urethane. I told him he would like the four inches of urethane and that, based on my experience, urethane was a far better insulator than expanded polystyrene. He told me he felt sick – there was no way that could be true. But it was too late for him to do anything about it. If he could have, he would have changed the contract instantly, but he was stuck and he felt stuck.

He owned twelve other similar-size freezers, all insulated with expanded polystyrene. They normally operated with three large compressor assemblies. During the summer, two compressors kept the building cold, while the third stood by in case one of the first two had a problem.

About a year later, I received a phone call from one of the managers. He asked me if I had time to insulate another 60,000-square-foot freezer in Clearfield, Utah. I assured him we had the time, the inclination, and the excitement to do it, but I thought the owner wanted nothing to do with urethane foam insulation. The manager explained that not only had the Clearfield freezer operated better than any other freezer in their line, it had operated for less than half the cost of the others. So, they were adding another 60,000 square feet without adding more compressors. The compressor power available to them because of the urethane insulation’s efficiency allowed them to do that. The building had run very nicely through the hot part of the summer with just one compressor. Now they would be able to run two buildings off two compressors and still have a spare.

Again, this is anecdotal evidence, but let me assure you that you will get the same results if you do as we did. I have insulated many buildings and I know what results you can expect. You cannot get a R-value from a fiber insulation and compare it to the R-value of a foam insulation. Nor can you use the R-value of a foam insulation if it is in sheet form and compare it to the R-value of spray-in-place foam insulation. Spray-in-place polyurethane is an absolute minimum of three to ten times as effective as any other insulation available today.

“Urethane Conserves Energy”

“Excellent thermal resistance is the primary performance benefit of urethane foam insulation, but it is not the only one. Urethane also has these advantages as a construction material: Its closed cell structure makes urethane most effective initially and in the long run. When protected by skins or other covering, urethane will not absorb water. Consequently the x-factor (thermal conductivity) is virtually constant. Sprayed-on foam has the advantage of no seams or joints. Urethane’s thermal resistance means that only one thickness of material is needed for most jobs. It has a low moisture permeability (1-3 perms).

“Where circumstances demand thinner walls or roofs, urethane – with its superior insulating capability – makes it possible to reduce the thickness of the insulation component with no loss of thermal resistance. Or the thermal resistance of an assembly can be increased without enlarging the size of the member. Urethane helps to offset the design restrictions imposed by the fact that most building materials are constant in thickness and weight.” (Mobay Chemical Corp. “Urethane Foam as an Energy Conserver,” How to Conserve Energy: in commercial, institutional and industrial construction, Pittsburgh, PA, 1975, 3)

During the late 1970s, the FTC (Federal Trade Commission) went after urethane foam suppliers for misleading advertising, especially regarding fire claims. A consent decree followed. It destroyed a tremendous amount of confidence in the use of urethane. Up to that point, Commonwealth Edison gave Gold Medallion approval to homes insulated with only one quarter inch (0.25″) of spray-in-place urethane in the side walls of masonry constructed homes. Much work was done in the early 1970s using a 1.25 inches urethane as a replacement for wall insulation in a home. Not only did it replace the wall insulation, it also replaced the exterior sheathing. Buildings are stronger and better insulated when sprayed with the 1.25 inches of urethane.

Insulation has two purposes: to cut heat loss and to control surface temperature.

I. Heat loss:

This next section covers aspects of insulation that most people are unfamiliar with or don’t know very well. There is a substantial difference between insulation for temperature control and insulation for heat loss control. For instance, the graph shows the heat loss control of spray-in-place urethane foam insulation. Any insulation will have a similar graph but with thicker amounts of insulation. This graph points out that more insulation is not necessarily cost effective. From a heat loss perspective, there is a point at which more insulation is pointless.

The graph shows that 70% of heat loss from conductance is stopped by a one-inch thickness of spray-in-place urethane foam. See Figure 4.5 Note: Nearly 100% of the heat loss from air infiltration is stopped with the first one-fourth of an inch of urethane foam. The second inch of spray-in-place urethane stops about 90% of heat loss, and the third inch stops about 95% and so forth.

pastedGraphic 10 The R value is a modern fairy tale.

Figure 4.5

This graph illustrates a building’s reduction in heat loss when it is insulated with various thicknesses of spray-in-place urethane foam. Note: Above 3 inches, the insulation benefit tops off quickly. The graph is not exact, but it shows, in general, what happens as additional insulation is added to the surface temperature. In other words, by super-insulating, the surface temperature of the inside of the exterior walls comes very close to the room temperature. This prevents condensation, that, in turn, prevents mold growth.

Thermal Diffusivity and Heat Sinks

It should be noted here that when urethane is used on the exterior of a heat sink, such as concrete, the actual effective R-value is approximately doubled. Consequently, for a Monolithic Dome, we are able to calculate effective R-values in excess of 60. A heat sink is any substance capable of storing large amounts of heat. Most commonly, we think of concrete, brick, water, adobe and earth as heat sink materials used in building. The property of a heat sink to act as an insulation is called thermal diffusivity.

Here is a simple explanation for the way it works: As the temperature of the atmosphere cycles from cold to hot to cold to hot, the heat sink absorbs or gives up heat. But because the heat sink can absorb so much heat, it never catches up with the full range of the cycle. Therefore the temperature of the heat sink tends to average. Large heat sinks will average over many days, weeks or even months.

An adobe hacienda with its two-to-six-foot thick walls exemplifies this process. By the time the adobe walls begin to absorb the daytime heat, it is night time, and the same heat then escapes into the cooler night. Therefore the temperature averages. Because of the adobe’s large mass, the temperature averages over periods of months. So, adobe acts as an insulation even though adobe has a minimal R-value.

According to the graph, urethane thicknesses beyond four or five inches are practically immaterial. We use three inches for most of our construction. Two inches will do a very superior job. We have insulated many metal buildings with one inch of urethane and got a dramatic drop in heat loss. Obviously the first quarter inch takes care of wind blowing through cracks. (It usually takes an inch to be sure the cracks are all filled.) The balance of the inch adds the thermal protection.

II. Surface Temperature Control

Surface temperature control is the second reason for insulation. In many cases, it is the most important reason. I noticed this phenomena first while insulating potato storages.

We had various customers ask us to insulate buildings with anywhere from two to five inches of urethane. But the building insulated with two inches would hold the temperature of the potatoes properly and just as well as the building insulated with five inches. The difference came in the condensation. Potato storages are kept at very high humidity levels. So, buildings with two inches of urethane would have far more condensation than those with five inches.

An engineer from the Upjohn company explained this to me. He stated that thicker insulation is absolutely necessary to maintain higher interior surface temperatures. One and a half inches of urethane on the walls and ceiling of a potato storage would control the heat loss from the building, but it took a minimum of three inches of urethane to control the interior surface temperature. Four inches was even better. With five inches the difference is practically negligible. The only place where we have felt the need for five inches of urethane was in insulating the roof or ceiling of a subzero freezer.

Underground housing: surface temperature control vs. heat loss control

Most underground housing gets in trouble from mold and mildew growth. The cause is not enough insulation to control interior surface temperatures. Rarely is there a problem with total heat loss. Water vapor condenses on the surface, allowing mold to grow. Mold makes people sick. The only solution is using lots of insulation for temperature control and ignoring total heat loss since it is not a factor.

Experience has taught me that R-value tables can be used as indicators. But they need modifications to make them equal to real world conditions. Allowances must be made. They must show equivalents. These equivalents should indicate that one inch of spray-in-place urethane equals four inches of fiberglass in normal installations. Footnotes to the table should define degradation of insulations in real world conditions. Only then will the R-value Fairy Tale become a real world success story.


Tags : , , , , , ,
Posted in : Cost, R-value, Return on Investment | 12 Comments »

What do you risk by not using Spray Polyurethane Foam Insulation?28 April

High rise living room 300x224 What do you risk by not using Spray Polyurethane Foam Insulation?

Spray Polyurethane Foam Insulation

Why Spray Polyurethane Foam Insulation?

Spray Polyurethane Foam Insulation (SPF) addresses the three main deficiencies in todays building insulation  – low whole wall R-Values, moisture damage due to vapor permeability and air tightness.

Insulation is used to stop heat loss and conserve energy, but todays materials fail to do an effective job of this on several counts.  Heat is lost in three ways, radiation, convection and conduction.  Of these, convective heat loss (movement of air – and heat with it from one area to another) is the most significant accounting for 60% of total heat loss.  Conduction accounts for another 32% with radiation responsible for the remaining 8%.

Spray Polyurethane Foam Insulation eliminates convective heat loss.

Convection occurs within your walls because of the thermal gradient across the wall assembly.  On the warm side of the wall, air is tends to rise and on the cold side of the wall, air will sink where air movement is not prevented.  This readily occurs in fibrous materials in conventional wall assemblies.  Spray Polyurethane foam insulation, however, eliminates convective heat loss because of its closed cellular structure preventing the movement of air through the material.  In doing so, it entirely eliminates the most significant source of heat loss in the thermal envelope.

Conduction is addressed by the measurement of R-Value.  In as little as 3.3” of closed cell SPF, an R-Value of R20 can be achieved reducing conductive heat loss exceeding the performance of 6” of fiberglass.

While neither fiberglass nor closed cell SPF addresses radiation, the effective whole wall performance of a closed cell SPF wall assembly will significantly outperform today’s fibrous materials by a considerable margin.

Protect your home from moisture damage with Spray Polyurethane Foam Insulation.

Moisture damage occurs due to vapor drive, condensation and water ingress.  Key to eliminating vapor drive is the use of a vapor impermeable material.  While 6 mil poly perfectly installed, completely sealed at top and bottom plates and transitions can serve as such until it is penetrated, poly fails when even small punctures are made in the product.  It is estimated that a one square inch hole allows as much moisture through a wall annually as 300 square feet of diffusion!  Because closed cell SPF is several inches thick, sprayed against the outside wall and bonded to the substrate (sheathing and studs), it forms a complete seal, not easily damaged by penetrations for wall hangings and electrical boxes.

Condensation is eliminated with Spray Polyurethane Foam Insulation.

Condensation occurs when a body of air is cooled sufficiently to condense moisture in the air mass.  Inside your walls, this occurs at the point in your insulation where the air becomes saturated.  If this occurs in todays fibrous products, moisture is deposited in your walls and can, over time, cause damage.  Closed cell SPF on the other hand does not breathe.  With the condensation point occurring inside the mass of SPF, there is not opportunity to deposit moisture eliminating this source of future damage.

Water ingress, regardless if it is due to a failed roof membrane, condensation or vapor drive requires that moisture be permitted a channel to escape.  A wall can dry to the interior or exterior but it must dry.  With SPF sprayed to the outside of the wall, and no poly sheathing on the inside of the wall, SPF provides readily available drying potential to the interior and a safer assembly than traditional fibrous products covered with 6 mil poly on one side and house wrap on the other.

Create an air tight home with Spray Polyurethane Foam Insulation.

Finally, closed cell SPF results in a very airtight structure.  While this requires the installation of mechanical air handling equipment to ensure sufficient fresh air supply, the mantra “seal it tight, ventilate it right” is the best rule to follow.  By providing direct control of air leakage, we can control air turn over and reduce heat loss due to ad-hoc seepage through wall assemblies.  Cost offsets can be found in downsizing  HVAC equipment due to lower natural air turnover.

By relying on traditional materials a home will consume as much as 50% more energy than is possible by installing closed cell SPF.  A wall assembly built with closed cell SPF reduces moisture related damage and therefore cost of ownership and increased air tightness improves on long term thermal performance as well as providing opportunity for cost offsets by reducing the size of mechanical equipment.

The long-term cost of this decision far outweighs the additional expense of upgrading to closed cell SPF.  This is to say nothing of the increased comfort in:

  • Climate control.
  • Quieter walls.
  • Less dust.
  • Increased structural rigidity.

Closed Cell Spray Polyurethane Foam Insulation is the next generation in high performance thermal barriers.

Closed cell SPF is the next generation of insulating material.  While more costly up front, the long term financial return when energy savings are accounted for results in significant savings over todays fibrous materials.  By reducing moisture related damage, increasing efficiency and comfort, Spray Polyurethane Foam is the solution to todays increasingly demanding building codes and energy conscious home owners.

Tags : , , , , , ,
Posted in : R-value, Return on Investment, building envelope | 7 Comments »

EcoLogic Spray Foam Insulation | Who we are and what we believe.27 March

huge great room EcoLogic Spray Foam Insulation | Who we are and what we believe.

Spray Foam, Quality Insulation

Our Goal, to provide you with the information you need about Insulation.

EcoLogic Spray Foam Canada exists to serve our customers.  Far from a cliche, this is our core value. From your first visit to our website (www.ecologicfoam.com), where we hope to address what questions and concerns you may have, to the first call you place to us, where you will find us informative and straight in our communication, we strive to give you what you want, without drama.  You’ll find we are often able to quote you over the phone, and that we are able to schedule your foam install with very little delay.

Competitively priced Insulation

We keep our prices competitive so that we can provide value while maintaining a high standard in all we do.  We are neighbors in Canada and the surrounding communities in which we work and we treat our clients as though they lived next door.  Our goal is not to sell you insulation, our goal is to educate, answer, respond to and provide you with the information you need to make informed decisions.  We know that by providing you with the information you need to understand the role of insulation in your home, how it interacts with the other building materials you use, and the role it plays in preventing moisture damage in your new home, you will be able to make the right choice for your family.

Our Insulation material leads the industry

EcoLogic Spray Foam is founded on the belief that we can live in harmony with our environment and that we can live in balance with the resources available to us.  Not only will using our foam insulation reduce the amount of fossil fuels needed to heat your home by half, it will lower your heating bills by just as much.  That is harmonious living, but we have gone beyond that and utilize recycled and renewable materials in our foam to further reduce the load that we place on our limited resources.  With soya bean oil and recycled plastic bottles making up a higher percentage of our total content than any similar product, we can boast that EcoLogic Spray Foam is as green as it gets.  Like all spray foams, we manufacture your foam at your site – this means that our product is transported to your Canadian home in its original state and this results in huge carbon savings by limiting the amount of energy that goes into transporting say – fully expanded fiberglass batts, which are bulky.

Your Local Insulation Contractor.

Give us a call today, we’re local and we’re ready to help.  We strive to earn the trust of all we work with and we believe that you will find we work hard at meeting your needs.  For a free insulation estimate, call us at 1 888-880-8420.

Tags : , , , ,
Posted in : Environment, R-value | Comments Off

Spray Foam Insulation Problems | Depth Control24 February

Cozy living Spray Foam Insulation Problems | Depth Control

Comfort provided by spray foam

Spray Foam Insulation problems, Depth control

Spray foam insulation is perhaps the most significant new building product on the market.  Amidst all the hype of green materials, LEED certification points and environmentally friendly new products, spray foam insulation alone stands out as the biggest game changer in the push to build more efficient homes.  The results are home that consume 50% less energy to heat them, are far more comfortable and have better indoor air quality.

Spray foam and the Building Envelope

Properly applied, spray foam insulation creates a continuous building envelope with no gaps or cracks through which air and moisture can enter or escape, but problems arise when spray foam is not properly installed.

Spray Foam generates heat

When installed, spray foam is applied by mixing two highly reactive materials in an airstream as they leave a spray gun.  This reaction creates heat as it forms bubbles and rises to form foam.  This heat will escape as the foam cools and a good installation allows the foam to cool fairly evenly.

Properly installed foam is applied at a depth not greater than 2” deep.  This allows the foam to cool reasonably consistently from the outside, in.  When foam is installed at greater depths than this, it cools unevenly.  The interior core of the foam will remain hot long after the exterior has cooled.  This creates stress within the foam and can result in foam that pulls away from the wall or studs and even foam that cracks.  When this happens, it is not generally seen as a small shallow crack but a deep fissure to the core of the material.

A good spray foam installer won’t take short cuts

There are several reasons that a foam installer may apply a layer greater than 2”.  These reasons may include inexperience, but more likely are a result of commercial pressure to increase the yield of the material, which can be achieved by applying it in thicker layers.  If your contractor has under bid the job and wants to stretch the material he installs he can accomplish this by laying foam a little deeper.  This is contrary to the CAN/ULC 705.2 specification which details how foam is to be installed.

Some products are to be avoided

While not common, there have been a number of incidences in Eastern Canada with a product introduced this past year, which have resulted in house fires that have burned the structures to the ground.  This has resulted when a significant depth of a competitors foam product is installed at once and the trapped heat in the interior of the material cannot escape and eventually combusts.  This is not common and yet it also points out the importance of knowing what product is being sprayed.

While it is difficult to monitor your foam installation because the installation process requires WorkSafe safety gear be worn, hiring a reputable installer who can supply references is a good first step.

Please feel free to contact EcoLogic Spray foam to discuss any questions you may have.

Tags : ,
Posted in : Common Questions, Environment, R-value | Comments Off

EcoLogic On SIte: Langley, BC24 April

EcoLogic Spray Foam now offers an innovative solution to homeowners who have shied away from using foam due to the cost of application.

As shown in this video, we can install R-14 Roxol Batts to your homes walls and then spray onto them as a substrate. The result is a high R value wall system with the advantages of foam including its air barrier and vapor barrier properties as well as its high thermal resistance, at a lower cost.

While not as efficient as a complete foamed wall, this offers an alternative to homeowners who are on a tight budget that has until now precluded the use of foam in their walls.

Call us to see if this application is right for you 1-888-880-8420.

Tags : , , , , ,
Posted in : Cost, R-value, Video | 3 Comments »

You’re an expert in home comfort.28 March

.

At EcoLogic, we’re experts are in Creating Comfortable Homes.

Let’s Talk

If you’re like most folks, by the time you’re ready for your first house you’ve already become a home comfort expert. Because we’ve all lived in houses growing up, with comfortable rooms that people gathered in and uncomfortable rooms that folks just passed through.

new home2 300x199 You’re an expert in home comfort.

Energy Efficient New Home

And all of us have visited and stayed at relatives and friends. We know a cold, drafty, clammy room when we’re in one! So we’re all home comfort experts, but not many of us know exactly how to build a house that will provide a warm, comfortable environment for our families and loved ones.

At Ecologic, our spray foam insulation technology replaces conventional insulation materials to provide you with more comfort at reduced energy levels. This advanced building technology works by addressing the three major causes of home discomfort: heat loss, air leakage and moisture. Ecologic’s foam technology attacks these three comfort challenges in multiple ways.

First, it is a superior insulation product. With an R-6 rating per inch of foam, it is a superior insulator to conventional fiberglass batts.

Secondly, because it is applied by spray, it gets into every nook and cranny between the inside and outside walls of your home. By doing so, it prevents the air leakage that conventional insulation allows, since cold air will travel around the edges of conventional insulation the way cold air will blow through the edges of an ill-fitting window.

Lastly, Ecologic’s spray foam is an approved vapor barrier, blocking not only moisture, but also pollutants, dust, odors and allergens. It provides the peace of mind that comes with knowing that you are creating a healthy interior environment for your family.

What about affordability?

Ecologic’s spray foam insulation is a premium building product, like granite countertops or custom windows. It will add to the cost of building your home. For a typical mortgage on a new house, it will add perhaps $20 to $30 a month to your monthly mortgage payment. But it is still a money-saving bargain. How can that be? Because typically you can expect to use between 40% to 50% less heating energy by applying Ecologic’s spray foam insulation when your home is built.

The energy cost savings almost always exceed (and often far exceed) the increased mortgage cost. As for retrofitting an older house, the financial formula is not the same, but the payback will likely be around 4 to 5 years, after which you will enjoy a net cost saving every month. If the future were to bring unreasonable increases in the cost in energy, your foam insulation would serve to hedge you from those distressing increases.

Why the “Eco” in Ecologic?

At Ecologic, we’re proud that our technology is environmentally responsible. The foam is made from recycled polyurethane (think ‘chopped-up used milk bottles’) mixed with soya oil, a bio-oil free of petroleum. We spray it on using a ‘zero ozone depletion’ propellant that is safe for the atmosphere.

Tags : , , , , , , , ,
Posted in : Common Questions, R-value | 2 Comments »

Is R value relevant?17 February

R-Value has long been part of the building and construction industry as the measure of thermal performance of a structure.  It is generally accepted that higher R-Value equates to more efficient building insulation. Spray Polyurethane Foam (SPF) has changed some of the most common beliefs associated with R-Value.

To start, a couple definitions:

Conduction: transfer of thermal energy between neighboring molecules in a solid substance such as insulation.

Convection: movement of air molecules through insulation which carry heat energy outside the building envelope.

R-Value is a measure of a material’s resistance to heat transfer.

Conduction typically accounts for 20% of a building’s heat loss, while convection accounts for up to 80% of the energy loss depending on the quality of construction. Any convective loops inside the insulation material are taken into consideration by the R-value test method, but air leakage through the entire composite building envelope is not considered at all. Closed cell spray foam at ¼” can stop 80% of heat loss by convection and at 3″ will prevent 95% of heat loss by conduction. Obviously, the same holds true for an air-conditioned structure.

Common Questions:

“The higher the R-Value the better, correct?”
Yes, higher R-Value in your home or building is somewhat better; however, its importance is overemphasized.  SPF’s ability to create an air-tight seal for your home is the most important factor in creating an energy-efficient, comfortable, and healthy home. About 80% of the energy loss of your home or building is caused by unwanted and uncontrolled air flow through the walls, ceilings and floors.

“What is the R-Value of your product?”
R-Values vary by manufacturer. EcoLogic is proud to provide its Soy based, spray foam system which provides an R Value of over 6 per inch of depth.

Basement Walls 1s 300x224 Is R value relevant?

Air tight seal

Closed cell Spray Polyurethane Foam offers higher R-Values per inch than conventional insulating alternatives.  Most importantly, only spray foam provides total air tightness. As a matter of fact, just 2 inches (5 cm) of closed-cell foam provides a vapor barrier. No other insulation system can provide that! When considering your insulation choices, the air-tightness alone should be a compelling reason to insulate with SPF.

Tags : , , , , , , , ,
Posted in : R-value | 8 Comments »